1200 A Bus Extension (Indoor/ Outdoor Cu bus)
|
Single-phase, three-wire Bus Extension
(6 in. wide)
|
EZM1EXT6
|
|
Single-phase, three-wire Bus Extension
(12 in. wide)
|
EZM1EXT
|
|
Three-phase, four-wire Bus Extension
(6 in. wide)
|
EZM3EXT6
|
|
Three-phase, four-wire Bus Extension
(12 in. wide)
|
EZM3EXT
|
|
1200 A Bussed Corner Sections (Indoor/Outdoor Cu bus only)
|
Single-phase, three-wire Inside Corner (14.75 in. wide)
|
EZM1CORNER
|
|
Single-phase, three-wire Outside Corner
(6.20 in. wide)
|
EZM1ELBOW
|
|
Three-phase, four-wire Inside Corner
(14.75 in. wide)
|
EZM3CORNER
|
|
Three-phase, four-wire Outside Corner
(6.20 in. wide)
|
EZM3ELBOW
|
|
1200 A Transition Sections— Old to New
(10.7 in. wide Cu bus)
|
Add right of old style single-phase
EZM lineup
|
EZM1TRANR
|
|
Add right of old style three-phase
EZM lineup
|
EZM3TRANR
|
|
Add left of old style single-phase
EZM lineup
|
EZM1TRANL
|
|
Add left of old style three-phase
EZM lineup
|
EZM3TRANL
|
|
Mounting Channel
|
72" long
|
EZM72MC
|
|
Secondary Surge Arrester Mounting
kit
|
For use with 1 or 2-SDSA1175 or 1-SDSA3650 (order surge arrester
separately)
|
MMSAMK [1]
|
|
Stud Kit for EZM-TB 400–600 A terminal box
|
Includes (2) 1/2 in.-13 studs per pad and mounting hardware. Four
pads per kit.
|
EZMSK2
|
|
Al/Cu Lug Kits
(Each kit includes
three, 2-barrel lugs.)
|
(1) 1/0–600 kcmil or (2) 1/0–250
kcmil per lug
|
MMLK250
|
|
(2) 3/0–500 kcmil per lug
|
MMLK500
|
|
(2) 2–600 kcmil per lug
|
MMLK600
|
|
Feed -Thru for EZM-TB 800 A Terminal
Box
|
(4) 750 kcmil Al/Cu lugs per phase and neutral. Al wire 600 A max.
Cu wire 800 A max.
|
EZM600FTLK3
|
|
Feed-Thru for EZM-TB 1600 A Terminal
Box
|
(24) additional lugs, 600 kcmil Al/Cu,
(6) per phase and neutral.
|
EZM1600FTLK3
|
|
EZM Mains
Right Side Closure Cap
|
Replacement right side end cap for
EZM Cross Bus Opening
|
EZMSCAP
|
|
EZM Mains
Left Side Closure Cap
|
Replacement left side end cap for
EZM Cross Bus Opening
|
EZMCAP
|
|
Fifth Jaw Kit
|
1 per kit
|
5J [2]
|
|
Horn Bypass Kit
|
Use with Type EZMR single-phase meter socket only
|
MMHB
|
|
Slider Type Manual Circuit Closer
|
For (1) 125–225 A ring-type socket only—indoor/outdoor
|
MM200MB [3] [4]
|
|
Anti-inversion Clip
|
Rejects 100 A and 200 A watt-hour
meters in Class 320 meter sockets in Type EZML branch units.
|
MMLRK
|
|
QO Adapter for bolt-on Q-frame tenant
circuit breakers
|
For 2P Type QO (40–125 A, 10
kA max. meter center SCCR) or QO-VH and QOH (40–60 A, 100 kA
max. meter center SCCR)
|
EZM125QOA
|
|
LJL Circuit Breaker Alternate Lug (DE2)
|
Kit includes (3) separate lugs for (1) #2 AWG - 500 kcmil Al or (1)
#2 AWG - 600 kcmil Cu per lug.
|
AL400L61K3
|
|
LJL Circuit Breaker Seal Kit
|
Tamper-evident kit to seal LJL trip
dial cover, (1) per circuit breaker, if required. Meets NEC 240-6
[c]
|
MICROTUSEAL
|
|
Meter Socket Closing Plates
|
Lexan Closing Plate—EZM, EZMR,
EZMH, EZMT
|
29007
|
|
Metal Closing plate—EZMR, EZMH,
EZML
|
RSG4
|
|
Sealing Rings
|
Snap-on (Stainless Steel)
|
ARP00026
|
|
Screw-Type (Aluminum)
|
29008W
|
|
Latch-Type (Aluminum)-standard
|
2920910001
|
|
Barrel Lock Kit
|
For use on ringless EZM or MP branch
unit covers, includes 6 each of head protectors, lock nuts and sealing
caps. (Barrel lock not included)
|
MMBLC
|
|
Tenant Circuit Breaker Filler Plates
|
125 A Branches—2P Type QO (2 per opening) 225
A Branches—2P and 3P Q-Frame
|
QOFP
|
|
Lug Landing
Kit
|
For use with EZM 1200 A Mains suffix
-CBU or -FSB. Order lugs separately
|
EZM1200ULL
|
|
Branch
Section Mounting Kit for Riser Applications
|
This kit is needed when installing
and connecting meter center branch sections to EZ-Meter Pak busway
center tap mains in multi-floor riser applications (1 per branch section)
|
EZMCTMKIT
|
|
Branch
Terminal Box: This device accommodates a maximum conductor
size of 300 kcmil when voltage drop calculations require sizes over
2/0.
|
The EZM3BTB accommodates oversizing
conductors of up to 3 circuits, mounts above or below a 125 A EZM
branch, and is rated NEMA 3R when below device, NEMA 1 when above
device.
|
EZM3BTB |
|
The EZM6BTB accommodates oversizing
conductors of up to 6 circuits, mounts above a 125 A EZM branch, and
is rated NEMA 1.
|
EZM6BTB
|
|
Load Center Main Lug Kit 125 A
|
125 A main lug kit for load centers, supporting larger wire sizes
6-4/0.
|